Home | 中国語 | 日本語 | Contact Us
 MUSASHI
 HOYA
 YAMATO
  Drying Oven
  Muffle Furnace
  Incubator
  Sterilizer
  Water Bath
  Rotary Evaporator
  Water Purifier
  Spray Dryer
  Shakers
  Electronic Equipment
  Bio-Technology Related   Instruments
  Plasma Reactor / Cleaner
 DRYZONE
 DIC
 KOKI
 OTHERS

Contact person: Mr.Hu
Tel: 0411-87300505
Fax:0411-87305556
Mobile: 13940906200
E-mail: fenghu@chjtech.com
Factory Address:
NO.5,HuaiheRiverthreegroups,
Economicdevelopmentzone,Dalian

 
首页>products>YAMATO>Bio-Technology Related Instrum> Details
Genopattern Analyzer GP1000
 
 
 

GP1000

SIMPLIFY ANNOYING IDENTIFICATION OF BACTERIUM AND VIRUSES.
CATCH ACCURATE DATA AT GENE LEVEL RIGHT NOW.

- Possible to identify each bacterium and viruses in the shortest 30 minutes (*) by the pattern analysis of "DNA Dissociation Wave" -

This is the newest analyzer using GENOPATTERN method, which is developed from the creative imagination. The base sequence of bacterium, viruses and all others is to be analyzed.

  • No need to extract DNA samples - Sequential operation is possible from the reaction of a single-strand extension to the pattern analysis of wave.
  • Everybody easily operates and uses the analyzer, which makes their operation errors reduced.
  • No genome extraction is required, because test specimens (microbes, cells) become directly the test sample to be analyzed. (*2)
  • High accurate temperature distribution is available over all well (48 samples) with individual zone temperature controller.
  • Accurate wave pattern is obtained with step less temperature controller and rapid data scanning.
  • Genera and species of bacteria and virus are classified and identified very easily by “Geno Master”. In addition, the master wave pattern can be registered.
  • Most genes of animals, plants, microbes can be analyzed through the primer that is produced with the software “DESIGN SUPPORT TOOL FOR GENOPATTERN PRIMER” (*3).
  • Available for a broad varieties of applications such as the inspection of infectious diseases to domestic animals & pets, the analysis of food allergy caused by food genes, the group expression of adverse drug reactions, the diagnosis of body predisposition or so.

MEASUREMENT FLOW:

1.Input the program data of the temperature and time, which are necessary to the wave pattern analysis and the reaction number of single-strand extension.

 
3. Set samples   2.Put the sample and reagent into sample tubes.
 
4. Start   5. Preparation process / wave pattern analysis / preparation process for wave pattern analysis: single-strand DNA extension reaction
(approximately 30 min. to 2 hours).
 
6. Identify bacterium or viruses by pattern analysis software (Geno Master).

Specifications:
Product Code 317110
Model GP1000
Temperature Setting range 0-100°C
Temperature Rising Speed 1.6°C/sec
Temperature Falling Speed 1.4°C/sec
Temperature Rising/Falling Method Peltier modules
Number of Sample·Tube Capacity 48 samples·200µL
Sample Capacity 50µL
Light Source Blue LED
Photo Detector Photo Multiplier
Power Source AC100V 700W
 
 
 