| Natural Convection by Air Jacket 402/602/802 |
| |
 |
|
Incubators of natural convection by air-jacket, equipped with various functions. They are equipped with a newly developed controller, and can be operated by an interactive key input, and are also equipped with a temperature memory function.
Features:
- The air-jacket method makes it possible to uniformalize the distribution of temperature.
- Setting can be made digitally using the dedicated operation menu keys or the keys, setting, measuring and over-heat setting temperature are displayed simultaneously.
- Samples can be observed through the inner door.
- Equipped with self-diagnosis function, a key-lock function and an over current breaker.
- Possible to place the models IS402/602 in piles, one over the other.
|
|
Specifications:
| Model |
IC402 |
IC602 |
IC802 |
|
Performance
|
| Circulation method |
Natural convection by air jacket |
| Operating temperature range |
Room temperature +5 to 80°C |
| Temp. adjustment accuracy |
±0.5°C (at 37°C) |
| Temp. distribution accuracy |
±1.0°C (at 37°C) |
Components |
| Interior Material |
Stainless steel SUS 304 |
| Exterior material |
Electro-galvanized steel sheet with melamine resin baking finish |
| Heat insulating material |
Glass wool |
| Heater |
Iron-chrome wire heater, 0.3KW |
Iron-chrome wire heater, 0.4KW |
Iron-chrome wire heater, 0.7KW |
Controller |
| Temp. controller |
PID control by microprocessor |
| Temp. setting method |
Operation menu key and digital setting by  key |
| Temp display method |
Measurement temp. : Digital display by green LED Setting temp. : Digital display by red LED |
| Timer |
1 min. to 99 Hrs. 59 min. and 100 Hrs. to 999 Hrs. 50min. |
| Operation function |
Fixed temperature operation, quick auto-stop, Auto-stop, Auto-start |
| Additional functions |
Calibration off-set, Key lock function, Uninterruptible power for memory |
| Heater circuit control |
SSR control |
| Sensor |
Pt sensor, K-thermocouple |
Safe Device |
| Safety countermeasures |
Self diagnosis functions (temp. sensor abnormal, heater disconnection, SSR short, automatic overheat prevention), Key lock function, Electric leakage breaker with over current protection, Overheat prevention device |
Standard |
Internal dimensions (W×D×Hmm), External dimensions (W×D×Hmm), Internal capacity |
450×480×450, 560×606×820, 97 liters |
600×530×500, 710×656×870, 159 liters |
600×530×1,000, 710×656×1,619, 318 liters |
| Shelf plate with standard load |
Approx. 15 kg/piece |
| Shelf rest step number |
9 steps |
12 steps |
29 steps |
| Shelf rest pitch |
35 mm |
30mm |
| Power source 50/60Hz |
100V/220V, single phase, 3.2A/1.5A |
100V/220V, single phase, 4.2A/1.9A |
100V/220V, single phase, 7.5A/3.4A |
| weight |
Approx. 45 kg |
Approx. 65 kg |
Approx. 102 kg |
Accessories |
| Shelf plate |
Stainless steel, 2 pcs. |
Stainless steel, 2 pcs. |
Stainless steel, 4 pcs. |
| Shelf bracket |
4 pcs. |
4pcs. |
8 pcs. |
Optional Accessories |
| Stand / Additional shelf plate / Fitting for stacking / Temp. output terminal(4-20mA) / Cable hole(φ25mm,φ50mm) / Time-up output terminal etc. |
|
|
|
|
|
|